ERA50-SPD2H-BF
Modularized hot swappable power supplies to protect your valuable equipment from power circuit and power component failures
Airflow
Back to front
Operating Ambiant, normal mode (inlet air)
0~50°C (32~131°F)
Non-operating Ambient
-40~80°C (-40~176°F)
Storage Temperature
-40~80°C (-40~176°F)
Operating Humidity
20% ~ 90% RH non-condensing
Non-Operating Humidity
5% ~ 95% RH non-condensing
Temp. Coefficient
±0.03%/°C (0~50°C)
Operating Altitude
16,404 ft (5000M)
Weight
1000g
AC Connector
IEC320 C14 type 3 pin connector
DC Output Connector
Oupiin 9392-4S24P04N12CB30DA
Safety
UL, CB, FCC, CE
Dielectric Withstand Voltage
3sec / 1.5KVac or 2545Vdc with a trigger limit of10mA.
Surge Voltage
Line to Line : 1KV
Line-to-Ground: 2KV
MTBF
100Khrs min SR332 (25°C)
Dimensions
260mm x 106mm x 41.5mm (Lx Wx H)
Weight
2200g
AC Connector
IEC320 C14 type 3 pin connector
DC Output Connector
ATX
Safety
UL
CB
FCC
CE